Thank you for your interest in the NSN 5905-00-332-9671 associated with the part number 108219-006 and FSC 5905 Resistors featured on Alpha Aerospace Parts. On this page, entities may request a quote for their comparisons on Resistor Fixed Wire Wound Nonind items by Xerox Corporation with CAGE Code 18338 or begin the purchasing process through the submission of a completed RFQ form. This entails providing details regarding one’s desired part quantities, target prices, estimated shipping time frames, and more, as applicable. Upon submitting a completed form for part number 108219-006 our representatives will utilize their market prowess to supply you with a personalized quote backed by rapid lead times and cost savings in just 15 minutes or less
Proudly operating with AS9120B, ISO 9001:2015, and FAA AC 00-56B accreditation, Alpha Aerospace Parts also operates with a strict NO CHINA SOURCING pledge, ensuring all products purchased are shipped in tandem with their manufacturer trace documentation or qualifying certifications. Dedicated to only supplying premium NSN 5905-00-332-9671 product such as 108219-006 of the highest caliber, experience the simplicity of Alpha Aerospace Parts when you are on the market for specific Xerox Corporation parts with the CAGE Code 18338 today!
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5905-00-332-9671 Item Description: Resistor Fixed Wire Wound Nonind | 5905 | 003329671 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
108219-006 | C | 1 | C | A |
MRC | Criteria | Characteristic |
---|---|---|
AAPE | TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | -10.0 TO 10.0 |
AAPP | ELECTRICAL RESISTANCE | 2.500 KILOHMS |
AAPQ | RESISTANCE TOLERANCE IN PERCENT | -0.020 TO 0.020 |
AAQF | AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER | 70.0 |
AAQG | AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 145.0 |
AAQH | TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS | +0.0 TO 125.0 |
AAQZ | INCLOSURE METHOD | ENCAPSULATED |
AARB | TERMINAL TYPE | WIRE LEAD |
AARG | RELIABILITY INDICATOR | ESTABLISHED |
AARH | RELIABILITY FAILURE RATE LEVEL IN PERCENT | 0.010 |
ABJT | TERMINAL LENGTH | 1.500 INCHES MINIMUM |
ABPM | BODY DIAMETER | 0.219 INCHES MINIMUM AND 0.281 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 0.688 INCHES MINIMUM AND 0.812 INCHES MAXIMUM |
AEFB | POWER DISSIPATION RATING IN WATTS | 0.250 FREE AIR |
CBME | CUBIC MEASURE | 0.050 CUBIC INCHES |
PKWT | III UNPACKAGED UNIT WEIGHT | 2.5 GRAMS |
STYL | STYLE DESIGNATOR | AXIAL TERMINAL EACH END |
TEST | TEST DATA DOCUMENT | 18338-108219 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWI |
![]() |