Thank you for your interest in the NSN 5925-00-982-9657 associated with the part number 5925009829657 and FSC 5925 Circuit Breakers featured on Alpha Aerospace Parts. On this page, entities may request a quote for their comparisons on Circuit Breaker items by E C A Etablissement Central with CAGE Code SCY13 or begin the purchasing process through the submission of a completed RFQ form. This entails providing details regarding one’s desired part quantities, target prices, estimated shipping time frames, and more, as applicable. Upon submitting a completed form for part number 5925009829657 our representatives will utilize their market prowess to supply you with a personalized quote backed by rapid lead times and cost savings in just 15 minutes or less
Proudly operating with AS9120B, ISO 9001:2015, and FAA AC 00-56B accreditation, Alpha Aerospace Parts also operates with a strict NO CHINA SOURCING pledge, ensuring all products purchased are shipped in tandem with their manufacturer trace documentation or qualifying certifications. Dedicated to only supplying premium NSN 5925-00-982-9657 product such as 5925009829657 of the highest caliber, experience the simplicity of Alpha Aerospace Parts when you are on the market for specific E C A Etablissement Central parts with the CAGE Code SCY13 today!
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-00-982-9657 Item Description: CIRCUIT BREAKER | 5925 | 009829657 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
5925-00-982-9657 | 2 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
CQXF | Inclosure Protection Type For Which Designed | SANDTIGHT AND |
AKPX | Pole Quantity | 1 |
AAQL | Body Style | SINGLE POLE TYPE |
CQXF | Inclosure Protection Type For Which Designed | SHOCKPROOF |
CPLM | Maximum Continuous Load Current Rating Per Pole | 5.0 AMPERES AC AND |
AFJN | Fragility Factor | MODERATELY RUGGED |
PKWT | Unpackaged Unit Weight | 1.500 OUNCES |
BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
ABXD | Bushing Length | 0.250 INCHES NOMINAL |
AEFQ | Nonturn Device Length | 0.078 INCHES NOMINAL |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 120.0 AC AND |
FREQ | Frequency In Hertz | 400.0 SINGLE LOCATION |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 28.0 DC SINGLE LOCATION |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 2000.0 DC SINGLE LOCATION |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 800.0 AC AND |
AXHR | Mounting Facility Type And Quantity | 1 THREADED BUSHING |
CPRJ | Trip Release Method | THERMAL SINGLE LOCATION |
AEFP | Nonturn Device Radius | 0.388 INCHES NOMINAL |
ADAT | Body Width | 0.562 INCHES MAXIMUM |
AEFR | Nonturn Device Width | 0.110 INCHES NOMINAL |
CPRL | Trip Release Characteristic | TIME DELAY SINGLE LOCATION |
CPRQ | Reset Method | MANUAL |
CRCF | Trip Release Ambient Temp Rating | 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 145.0 SINGLE LOCATION |
CPRT | Manual Actuator Type And Quantity | 1 PUSH-PULL |
ADTV | Case Material | PLASTIC |
CPRW | Actuator Function | TRIP-RESET |
CPSM | Internal Trip Release Configuration | SERIES TRIP SINGLE LOCATION |
CPRX | Actuator Position Designation | AT POLE ONE |
CQJX | Nominal Thread Size | 0.438 INCHES |
ADAQ | Body Length | 0.750 INCHES MAXIMUM |
AEFN | Nonturn Device Location | AT 12 OCLOCK |
THSD | Thread Series Designator | UN |
AJWX | Mounting Surface To Terminal End Distance | 1.707 INCHES NOMINAL |
MRC | Decoded Requirement | Clear Text Reply |
APNQ | Arc Quenching Method | AIR |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 0.703 INCHES NOMINAL |
TTQY | Terminal Type And Quantity | 2 TAB W/SCREW |
CPLM | Maximum Continuous Load Current Rating Per Pole | 5.0 AMPERES DC SINGLE LOCATION |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 20.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
CPRH | Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 2.000 MINIMUM AT 200 PCT AND |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
CMLP | Thread Quantity Per Inch | 32 |
CQXF | Inclosure Protection Type For Which Designed | CORROSION RESISTANT AND |